.. Web site 161 The indicator on the printer Faults happen once the adapter turns orange, and also the printing printer adapter runs. Disconnect and hook up the fails. electricity adapter, electric power around the printer adapter again, and validate whether the printing is typical immediately after 1 moment. Website page 163: Electrical Security Inspection

one.two.2 Warning Labels Warning Labels This means Be sure to cautiously look at this guide in advance of use machine. The subsequent labels really are a. Do not place the device with a sloped area. Usually the accessible once the program unit might slide, causing particular injuries or maybe the system operates Using the cellular malfunction.

Don't use any cables aside from the cables provided With all the product by Mindray. 3. Utilize the cable offered with this system to attach the printer. Other cables might result in electric shock. Site fifteen: Mechanical Protection

three. Click the upper icon while in the display (prompts “Update” if you set the cursor on it), the update stage is carried out, if fails, you should ship to R&D Middle. Determine six-one Most important Keep an eye on Upkeep Monitor four. After update is effective, restart the equipment just after ability off for making the information powerful. HDD Partition ... Web site 91 structured report similar data file and DICOM viewing program Report report template obd.bin OBD facts file Variation.txt Variation file Remark Remark file AnatomyImage Anatomical photos Measurement Measurement library Doppler plan and similar boot configuration most important file and plug-ins, remote desktop server Multilanguage string file exe videoplay.

Find out greater diagnostic facts by extended check out from the anatomical construction on all convex probes.

Reduce off cable ties connecting the principle device on the display by diagonal reducing pliers, and afterwards pull out the corresponding cable plugs.

Explore much better diagnostic details by way of extended view of your anatomical construction on all linear probes

The DP-50 Specialist is really an impressive, significant-effectiveness Ultrasound Process engineered that may help you obtain the insights you need. The Process’s strong motor and large-velocity processing supply excellent picture excellent and a complete facts administration Answer.

Purpose: On the back-finish of the most crucial board, a special check IC is employed to watch sign voltages  and clock battery ability which can be provided to the principle board by the principle unit box electrical power source module.

Immediately after profitable connection, the newly included network printer name is going to be proven while in the printer driver checklist. Observe: Just before hook up the community printer, be certain the ultrasound system and also the printer are in exactly the same community domain, as well as network is Operating Ordinarily. The IP deal with and the server title should be valid, e.g. Web site 47 DICOM Environment  Enter the AE Title of the ultrasound program, port and PDU according to the real condition, and after that click on [Alright] to exit the display.

Page 45 Return “Printer Company” webpage, Find the corresponding service with the printer listing and increase the service. The program integrates drivers of HP printers, right after HP printers are linked, drivers are going to be put in automatically (about 10s).If vehicle set up fails, icon will Show on the proper decreased corner of your monitor to alert you that handbook installation is critical. Website page 46: Network Preset

Optimum four occasions tasking for just one transmitted beam, leading to superb time resolution and higher frame price.

Following changing the CPU module, key file must be produced Once more based on the new MAC address and published into HDD of your equipment. Or else, the configuration functionality in the merchandise will likely be shed. Just after taking away the CPU module, Eliminate panhead screws with washers (twelve M3X6) fastened on the main unit box, you normally takes from the board. Website page 118 Determine eight-29 Disassemble the Control Panel Assembly (1) Hold the upper fringe of user interface assembly, and open up up the user interface. Figure 8-thirty Disassemble the Control Panel Assembly (two) After eliminating 1 countersunk head self-tapping screw PT3X10 preset about the control panel and take out the plug of the keyboard and the principle unit connecting cables, you could eliminate the user interface assembly.

Performance Examination 5.5.one Exam Process Resolution Detection depth Geometric Situation Accuracy Blackout area check History the exam photos five.five.two Test Articles The impression applied here is only for reference, persist with the image influence in the real Be aware: predicament. Prerequisites: Display screen: set the distinction and brightness within the medical software value (or the default position) Operation surroundings: dim room, simulating the medical software ecosystem. Site seventy six In condition the transverse resolution tests targets are horizontally displayed, file the negligible length of two targets which can be clearly recognized. Repeat the operation over to the transverse resolution testing targets at other depths. As revealed in determine below. Axial resolution ... Site 77 When using the convex probe, preserve the transverse resolution testing targets to NOTE: be shown close to the midline. When utilizing a linear probe with steer function, tend not to turn on the steer functionality when complete the transverse resolution test. Zoom during the region in which the targets Positioned if necessary. The diameter in the focus on issue at a certain depth is equal for the transverse resolution for the depth. Page 78 5.

Mindray respects your privacy. We use cookies for various uses, such as website functionality, increasing your encounter of our Web site, creating integration with social websites and serving to focus on our advertising and marketing.

five.2.3 Geometric positioning accuracy Longitudinal geometric positioning accuracy  Check Phase: Do adjustments as the best way in screening the utmost depth. Document the distance by 20mm Every single section on the longitudinal targets line using the measurement caliper; Decide on the worth with the greatest mistake (to 20mm), compute the precision using the formula under The measurement caliper must be positioned in the upper fringe of the target, Observe:... Page 79 Transverse geometric positioning precision  Check Action: Cover the scan surface of your phantom with water or couple gel, Carefully Get in touch with the probe Using the scan surface Regulate the depth, generating the transverse targets to generally be shown while in the graphic. Modify the focus point to generally be posited beside the transverse targets (the standard will not be very clear) Modify parameters like acquire, TGC, generating Every single transverse targets to generally be Obviously exhibited. Website page eighty 5.five.two.four Blackout Place Examination Move: Cover the scan surface from the phantom with h2o or couple gel, gently Call the probe Together with the scan floor Alter the depth in a lower worth, Dp50rb login and set the focus at the nearest location to the scan floor. Decrease the value of parameters like AP, Attain until finally the background sounds just is usually noticed. Website page eighty one: Software Improve And Routine maintenance